Free IAAI-CFI Practice Test: 25 Questions with Explanations

These 25 questions come from our IAAI-CFI course bank and are spread across the areas of the exam outline. Answer all 25, press the button at the bottom, and you will see your score by area, the correct answer to each question and the reason every other choice is wrong. No account is needed. The IAAI-CFI exam has no more than 100 true/false and multiple-choice questions, closed book, in 2 hours.

  1. Cause Determination, Classification and Failure Analysis

    On home oxygen at 3 L/min, a patient was lighting a cigarette with a disposable lighter when his flame-resistant blanket caught fire and burned completely. Defense counsel cites published tests, run under standard laboratory conditions, showing the blanket self-extinguishes after exposure to a lighter-size flame. What most limits the weight of those tests in this case?

  2. Cause Determination, Classification and Failure Analysis

    While filling a tiller, a homeowner spilled most of a 5-gallon can of gasoline on a basement floor. About ten minutes later a flash fire started at the gas water heater 15 feet away, just as its burner cycled on. In the cause statement, what is the first fuel ignited?

  3. Cause Determination, Classification and Failure Analysis

    Only ash and springs remain where a sofa stood at the origin. To state what the first fuel was and what it was made of, the investigator needs data about the sofa before the fire. Which source is most useful for that purpose?

  4. Origin Determination Methodology

    A monitored fire alarm panel in a burned office building was destroyed, and its internal event history cannot be recovered. The investigator still needs the order in which the building's addressable detectors reported. The best remaining source is

  5. Origin Determination Methodology

    The dispatch center's recording of an occupant's 911 call captures her saying the fire is "in the back bedroom closet." Two days later, after talking with relatives, she tells the investigator it started in the hallway. For origin analysis, the recording is most valuable because it

  6. Fuel Gas, Building Systems and Fire Protection Data

    Electric resistance heat strips in an attic air handler kept operating after the blower motor seized days earlier, because the thermostat kept calling for heat. Fire damage centered on the heater cabinet and the adjacent duct insulation. The safety controls whose failure should be tested first are the

  7. Origin Determination Methodology

    First in alarm on an addressable panel's log was a smoke detector in a second-floor conference room, 40 seconds before a detector in the copy room next door. The copy room door was closed and its return air duct was running. Treating the log as origin data, the investigator should

  8. Explosions, Incendiary Fires and Fire Deaths

    In January, gas leaking from a cracked main under a frozen, snow-covered street exploded in a house 60 feet away, while houses nearer the leak were unaffected. Excavation shows that the house's sewer lateral crosses the gas main trench. The most likely explanation for this pattern is that:

  9. Explosions, Incendiary Fires and Fire Deaths

    Propane leaked from a dryer connector in a basement laundry room and ignited. Candidate ignition sources include a water heater pilot 6 inches above the floor, a ceiling light the occupant switched on, a wall thermostat 5 feet up, and a refrigerator upstairs. Given propane's vapor density, the hypothesis to test first is the:

  10. Legal Considerations, Interviews, Testimony and Reports

    Hired a year after a house fire, a defense expert offers an origin opinion based only on the owner's recorded statement and six scene photographs. He never reviewed the fire department's report, the alarm panel log, the arc survey, or the 200 other photographs in the file. Of the Rule 702 requirements, the one most directly in question is

  11. Legal Considerations, Interviews, Testimony and Reports

    At a pretrial hearing in federal court, the defense challenges the plaintiff's origin and cause expert. The judge notes that Rule 702 was amended effective December 1, 2023, and asks who must establish admissibility and to what standard. The correct answer is

  12. Electricity and Fire

    Investigators recovered an e-bike battery pack of several dozen cylindrical cells, many vented and some ejected. To identify which cell failed first while preserving evidence for all parties, the best first step is

  13. Electricity and Fire

    Overnight, a wall-mounted lithium-ion energy storage system in a closed garage failed. Neighbors heard a loud bang, the garage door was blown outward, and only then did fire become visible. The most likely explanation for the sequence is

  14. Special Investigations and Major Case Management

    A delivery van caught fire after a 40-minute highway run. The valve cover gasket on the right bank had been leaking motor oil onto the exhaust manifold below it, and the heaviest damage centers on that manifold. The opposing expert argues that hot surface ignition of automotive fluids is rare, so the cause must be electrical. How should the oil leak hypothesis be treated?

  15. Special Investigations and Major Case Management

    Arc damage is found on a conductor of the blower motor circuit in a burned sedan. On this model the blower circuit is powered only through the ignition switch, with no retained accessory power after shutoff. The owner says the car had been parked with the key removed for two hours. What does the arc site establish?

  16. Electricity and Fire

    A fire began along roof deicing cable near a gutter. The circuit is protected by a ground-fault protection of equipment device set near 30 milliamperes rather than a 5-milliampere personnel GFCI. In the analysis, this device was installed mainly to

  17. Fire Effects, Fire Patterns and Their Interpretation

    A small, isolated burn on the carpet sits directly beneath a burned curtain rod, about 6 feet from the main fire area at a sofa. Fabric remnants and curtain hooks lie in the burned spot. A colleague calls it a second point of origin. What is the better explanation?

  18. Fire Effects, Fire Patterns and Their Interpretation

    In a home office, the deepest char and greatest material loss are at a bookcase packed with paper files, about 10 feet from a desk where witnesses saw the first flames. What most likely explains the heavy damage at the bookcase?

  19. Fuel Gas, Building Systems and Fire Protection Data

    An investigator comparing an older smoke alarm with a newer replacement learns that alarms listed to the 8th edition of UL 217 had to pass tests earlier models did not. Those added tests include

  20. Advanced Fire Dynamics and Fire Science

    Investigators planning a test burn want thermocouples that capture the hottest part of the ceiling jet 3 m from the plume centerline beneath a 3 m ceiling. The best placement is

  21. Advanced Fire Dynamics and Fire Science

    Beneath a smooth 3 m ceiling, with flames well below it, gas temperatures directly above a steady fire and 0.4 m from the plume centerline are nearly equal, while 3 m out they are much lower. Alpert's correlations explain this because the 0.4 m point lies within

  22. Fire Effects, Fire Patterns and Their Interpretation

    Burn patterns indicate fire spread from a bedroom into the hallway, but a neighbor reports seeing flames first at the hallway window. How should the investigator respond to this conflict?

  23. Advanced Fire Dynamics and Fire Science

    Cell phone video shows a fire in a round waste container 0.5 m in diameter producing mean flame heights of about 2.0 m. Rearranging Heskestad's correlation, L = 0.235 Q^(2/5) - 1.02 D, the heat release rate was about

  24. Physical Evidence and Laboratory Analysis

    After collecting a comparison sample of vinyl flooring from a hallway, the technician must package it. The correct handling is to place it in

  25. Physical Evidence and Laboratory Analysis

    A certified canine alerts strongly at one spot in the origin area, and the working hypothesis is that gasoline was poured there. Three samples from the spot are analyzed, and no ignitable liquid residue is identified. In the report, the alert should be treated as