Free Marine Fire Investigator Practice Test: 25 Questions with Explanations

These 25 questions come from our Marine Fire Investigator course bank and are spread across the areas of the exam outline. Answer all 25, press the button at the bottom, and you will see your score by area, the correct answer to each question and the reason every other choice is wrong. No account is needed. The IAAI Marine Fire Credential Endorsement (M) exam is taken on CFITrainer.net after IAAI approves the application; 70 percent passes and the score is not revealed. IAAI does not publish the number of questions or the time limit, so

  1. Vessel Examination, Recovery and Vessels in Structures

    As a raised vessel was dewatered, the cabin was photographed at three water levels. Afterward, the burned base of a table lamp is found against the aft bulkhead, well away from where the lamp was mounted. How should its final location be interpreted?

  2. Vessel Examination, Recovery and Vessels in Structures

    A raised houseboat is held at the surface by air bags while pumps remove the water inside. Fire debris lies on the cabin sole under about 2 feet of water. Which practice best protects small evidence during dewatering?

  3. Fuel, Ventilation and LPG Systems

    Tracing the LPG system on a burned motor yacht, the investigator finds the solenoid valve mounted under the galley counter, inside the cabin, rather than in the cylinder locker. A long supply hose ran from the locker to that valve. The usual location matters because a solenoid at the cylinder

  4. Fuel, Ventilation and LPG Systems

    Two weeks before a cabin explosion, a yard technician did a leak test using the gauge between the cylinder and the regulator. With all appliance valves off and the solenoid open, he opened the cylinder valve, noted the reading, closed the cylinder valve and waited. The gauge fell steadily while the boat's temperature stayed constant. The finding indicates

  5. Vessel Electrical Systems

    An arc bead is confirmed on a 120-volt galley circuit conductor near the area of origin, yet the circuit's 20-ampere breaker is found in the ON position. Opposing counsel's expert argues the bead cannot be an arc site because any arc would have tripped the breaker. What is the best response?

  6. Propulsion Systems

    During the examination of a burned stern drive cruiser, the exhaust riser is found separated from the manifold. The two broken mounting studs have fracture faces coated with soot and heat tint matching the surrounding surfaces. A salvor asks whether the studs broke when the boat was lifted. These fracture faces indicate that the break

  7. Propulsion Systems

    Fire on a sportfisher began in the engine room minutes after the crew heard a loud bang. The port engine block has a hole in its side with fractured edges bent outward, and a broken connecting rod lies inside. Oil coats the exhaust manifold and turbocharger above the hole. The most likely sequence is

  8. Legal Considerations, Evidence and the Exam

    The state reporting authority provides a copy of the boating accident report the operator filed after his cruiser burned at anchor. In it, he states his opinion that a faulty bilge blower started the fire. How should the investigator treat that opinion?

  9. Legal Considerations, Evidence and the Exam

    For 14 months, a burned houseboat has sat in a storage yard while claims were resolved. The insurer that owns it wants to stop paying storage and send it to scrap. Several interested parties examined it at a joint examination last year. What should come before disposal?

  10. Interior Spaces and Materials

    On the charred cabin sole of a trawler, there is a clean rectangular area about the size of a small cooler, with sharp edges and unburned varnish inside it. No cooler or similar object is anywhere nearby. What does the protected area most likely show?

  11. Interior Spaces and Materials

    Firefighters found the door to a forward stateroom standing open. The door's latch edge and a narrow band of its passageway face along that edge are clean and unburned, matching the shape of the door stop on the frame, while the rest of the passageway face is charred. What does this pattern indicate?

  12. Vessel Electrical Systems

    The DC distribution panel at the helm of a burned cruiser lies within the area of origin, and the investigator decides to remove it for laboratory examination. Its back is crowded with ring terminals, bus bars and partly melted conductors. How should the panel be removed?

  13. Vessel Electrical Systems

    An arc survey has located six arc sites in the burned cabin of a 34-foot sailboat, but the investigator cannot tell which conductors belonged to which circuits because the harnesses are fused together. What source will best support building the arc map?

  14. Fuel, Ventilation and LPG Systems

    The powered ventilation blower on a gasoline inboard draws air from the lower engine compartment. On a burned boat, the investigator traces the blower's outlet duct to see where the removed vapor went. For a proper installation, the outlet should lead

  15. Hull Construction, Exterior and Fire Behavior on Vessels

    Above the helm of a burned center console boat, the aluminum T-top frame melted and fell. The copper conductors of the electronics harness directly beneath it show no melting, and no aluminum dripped onto them. Using NFPA 921 melting data, what is the highest minimum temperature these observations support for the T-top area?

  16. Vessel Investigation Safety

    A commercial vessel burned in a busy channel, and the Coast Guard has established a safety zone around the wreck. The investigator's chartered boat plans to approach to photograph the hull. What must be obtained first?

  17. Hull Construction, Exterior and Fire Behavior on Vessels

    Aboard a burned aluminum-hulled fishing boat, the radar arch bent over and sagged onto the cabin top, yet its tubing shows no melted or resolidified metal anywhere. A trainee concludes the arch must have reached aluminum's melting range. What is wrong with this conclusion?

  18. Hull Construction, Exterior and Fire Behavior on Vessels

    Below a melted aluminum hardtop, two copper battery cables running along the cockpit side show silvery gray, pitted spots with small holes, and resolidified aluminum lies on the sole around them. How should the investigator first consider these spots?

  19. Vessel Investigation Safety

    A forepeak void on a steel fishing vessel stayed sealed for weeks after a fire in the adjacent hold. No smoke reached the void, but its bare steel plating is heavily rusted. What atmospheric hazard should the investigator expect inside?

  20. Vessel Investigation Safety

    Strong gasoline odor comes from the open engine hatch of a burned inboard runabout. Holding the meter at the hatch opening, the investigator reads 0 percent LEL with normal oxygen. Where should the sampling probe go next?

  21. The Marine Endorsement, Methodology and Vessel Terminology

    A yacht that burned in a boatyard was cut apart and hauled away before the insurer's investigator was assigned. The fire department and a marina consultant had taken about 300 photographs, drawn a deck plan and recorded measurements. How does NFPA 921 regard an analysis built on that material?

  22. Ignition Sources, Documentation and Cause

    Laboratory analysis of saloon carpet near the origin on a burned diesel-powered trawler identifies gasoline. Before treating the gasoline as foreign to the area, what should the investigator determine?

  23. The Marine Endorsement, Methodology and Vessel Terminology

    Before traveling to a marina, an investigator retained by a stern drive manufacturer's attorney is speaking with the client. Under the NFPA 921 basic method, what should she learn at this stage?

  24. The Marine Endorsement, Methodology and Vessel Terminology

    A 45-foot houseboat burned and partly sank at a lake marina, and a salvor will raise it next week. The investigator lists several tasks on her pad. Under the NFPA 921 basic method, which task belongs to the preparing for the investigation step?

  25. Ignition Sources, Documentation and Cause

    Full room involvement of a houseboat's saloon occurred before firefighters arrived. The carpeted cabin sole shows irregular, curving burned areas with sharp edges. No samples have been tested. What can the investigator conclude from these patterns?