These 25 questions come from our IAAI-FIT course bank and are spread across the areas of the exam outline. Answer all 25, press the button at the bottom, and you will see your score by area, the correct answer to each question and the reason every other choice is wrong. No account is needed. The IAAI-FIT exam has 50 selected-response questions taken online through CFITrainer.net; 70 percent passes and two attempts are allowed within 90 days.
Close to a wall, a burning chair produced a pattern with an inverted V at the bottom and a V above it, joined at a narrow waist. What is this pattern called?
Correct answer: A. Hourglass pattern is correct because a plume close to a vertical surface has a lower flame zone shaped like an inverted V and a hot gas zone above it shaped like a V. Where both contact the wall, the combined shape resembles an hourglass. The pattern indicates a burning item at or near the base of the wall.
- B is not correct because an inverted cone is a single triangle wide at the bottom with no V above it.
- C is not correct because a truncated cone is a three-dimensional pattern where the plume is cut off by the ceiling, shown on both the wall and ceiling.
- D is not correct because a saddle burn is a U-shaped char pattern on the top edges of floor joists, not a pattern on a wall.
Key point: Hourglass pattern
Reference: NFPA 921 (2024), Fire Effects and Fire Patterns
A pattern with a curved lower boundary appears on a wall, and its lowest point is higher than that of a nearby V pattern made by a similar fuel. What does the U shape most likely indicate about its heat source?
Correct answer: A. It sat farther from the wall is correct because NFPA 921 describes U-shaped patterns as similar to V patterns, with gently curved lower lines that are higher than the lines of a V, produced when the heat source is farther from the vertical surface. The plume widens before it reaches the wall, so the contact begins higher and is rounded. Comparing the lowest lines of U and V patterns helps estimate relative distance to their sources.
- B is not correct because a source touching the wall produces a V with a sharp low point at the base, not a raised curved boundary.
- C is not correct because pattern shape alone cannot identify a fuel, and the U shape reflects distance from the wall.
- D is not correct because the U shape reflects the geometry of the plume contact, and flame temperatures of ordinary fuels are similar.
Key point: It sat farther from the wall
Reference: NFPA 921 (2024), Fire Effects and Fire Patterns
A V pattern on a wall continues into a curved burn on the ceiling directly above it, showing the plume on both surfaces. What does NFPA 921 call this three-dimensional pattern?
Correct answer: B. Truncated cone pattern is correct because NFPA 921 describes truncated cone patterns, also called truncated plume patterns, as three-dimensional patterns displayed on both vertical and horizontal surfaces. The cone-shaped plume is cut off by the ceiling, leaving a V or U on the wall and a curved or circular pattern on the ceiling. Viewing the walls and ceiling together helps locate the plume and its fuel.
- A is not correct because an hourglass is a two-part pattern on a wall made by the flame zone and hot gas zone, without a ceiling component.
- C is not correct because an inverted cone forms when flames do not reach the ceiling, so it cannot continue onto the ceiling.
- D is not correct because those patterns appear on burned wall studs and describe stud height and shape, not a plume on two surfaces.
Key point: Truncated cone pattern
Reference: NFPA 921 (2024), Fire Effects and Fire Patterns
Crews knocked down a night fire in a large furniture store, but smoke, steam, and darkness kept the investigator from examining the interior. He left the scene and returned at 08:00 in daylight to begin the examination without a warrant or consent. A court asked whether this return was a continuation of the original entry within a reasonable time will base its decision on
Correct answer: C. The specific conditions encountered is correct because Tyler set no fixed time limit; reasonableness depends on facts such as darkness, smoke, steam, structural hazards, and the size and complexity of the scene. In Tyler, a return a few hours later in daylight was reasonable, while returns days and weeks later were not. Investigators should document the conditions that delayed or interrupted their work.
- A is not correct because the value of the loss has no bearing on how long a warrantless entry may last.
- B is not correct because Tyler set no fixed hour limit, and the Court instead looked at the facts of the scene, such as the smoke and darkness that delayed the examination.
- D is not correct because staffing of the department does not define the constitutional limit on warrantless presence.
Key point: The specific conditions encountered
Reference: Michigan v. Tyler, 436 U.S. 499 (1978); NFPA 921 (2024), Legal Considerations
One day after the scene was released, a rekindle call brings an engine back to the house. While extinguishing the hot spot, a firefighter sees a gas can with a cloth wick in plain view. This observation is lawful because
Correct answer: B. A new exigency justified the entry is correct because an active rekindle is a fire emergency, and firefighters may enter without a warrant to extinguish it and may note evidence in plain view while lawfully present. The authority is limited to the emergency and a reasonable time to deal with it. A broader search for evidence would need consent or a warrant.
- A is not correct because the scene release ended the original entry, so the new emergency is what justifies the return.
- C is not correct because no warrant was involved, and the earlier entry ended when the scene was released.
- D is not correct because releasing a scene returns control to the owner, whose privacy interest continues.
Key point: A new exigency justified the entry
Reference: Michigan v. Tyler, 436 U.S. 499 (1978); NFPA 921 (2024), Legal Considerations
A fire in the first-floor stud cavities of a two-story platform-framed house burned up the wall but did not run into the second-floor walls or attic, except along a plumbing chase cut through the framing. Inside the cavities, vertical fire travel was interrupted mainly by
Correct answer: B. Top and bottom wall plates is correct because platform framing builds each floor as a deck, and the wall studs for each story sit on a bottom plate and end at a top plate. These horizontal plates, along with the floor deck, close the stud cavity at every level. They act as fireblocking and keep a wall fire from running straight to the attic. A fire can still extend through openings in the plates, such as pipe and wire holes, so the investigator checks for penetrations.
- A is not correct because insulation may slow airflow but is not the structural element that closes the cavity at each floor.
- C is not correct because exterior sheathing closes the outside of the cavity but does not cap it vertically.
- D is not correct because a plastic or paper vapor barrier has no fire resistance and runs along the cavity face.
Key point: Top and bottom wall plates
Reference: NFPA 921 (2024), Building Systems
A free-standing masonry chimney leans toward the area where the team needs to dig. How should this hazard be handled?
Correct answer: A. Remove it in a controlled manner is correct because a chimney that has lost its bracing from the burned structure can topple without warning. It should be documented first, then brought down by equipment or qualified personnel before the team works within its fall zone. Its removal is part of making the scene safe for examination.
- B is not correct because speed does not change the collapse risk and keeps people in the fall zone.
- C is not correct because taping the base leaves the fall zone, which extends well beyond the base, open to workers.
- D is not correct because debris and loose timbers are not engineered support and can shift, and piling them may also disturb evidence.
Key point: Remove it in a controlled manner
Reference: NFPA 921 (2024), Safety
At a large multi-agency fire scene examination, a safety officer has been designated. What authority does this position carry?
Correct answer: B. Stopping unsafe acts immediately is correct because the safety officer monitors conditions and has authority to stop or change any activity that presents an imminent danger. That authority applies to every agency working at the scene. Origin and cause decisions, evidence handling, and release remain with the investigators and the person in charge of the scene.
- A is not correct because scene release is decided by the agency in control of the scene.
- C is not correct because it stretches the safety officer's role into the investigation itself; the safety officer can halt unsafe work, but which items are collected and how is decided by the investigators.
- D is not correct because the origin report belongs to the investigators who formed the opinions, not to the safety officer.
Key point: Stopping unsafe acts immediately
Reference: FEMA NIMS, Incident Command System (Safety Officer); NFPA 921 (2024), Safety
An excavator is lifting roof debris off the area of origin. Before stepping closer to look at an exposed item, what should the technician do?
Correct answer: B. Make eye contact with the operator is correct because the operator must know the investigator is approaching and stop the machine before anyone enters its reach. Eye contact and agreed hand signals confirm that the operator has seen the person and the bucket is idle. Investigators wear high-visibility clothing to make that contact easier.
- A is not correct because operators often cannot hear over the engine, so shouting does not confirm they are aware.
- C is not correct because timing a move between swings depends on guessing the operator's next action.
- D is not correct because the area behind an excavator is a blind spot inside the counterweight swing path.
Key point: Make eye contact with the operator
Reference: NFPA 921 (2024), Safety
Panel event history lists three addressable smoke detectors alarming in this order: storage room, corridor, office. For origin analysis, this sequence
Correct answer: C. Is data to test origin hypotheses is correct because the sequence shows when smoke reached each detector, which usually tracks distance from the fire but can be affected by doors, HVAC, ceiling features, and detector type. The investigator compares the sequence with patterns, witness statements, and fire dynamics. Panel data should be downloaded promptly, since some panels lose history when power and batteries fail. The device addresses must be matched to their physical locations.
- A is not correct because detector sequence relates to smoke spread and timing and says nothing about the ignition source.
- B is not correct because alarm data is objective time-stamped data, and NFPA 921 treats it as useful information.
- D is not correct because detector response also depends on spacing, ceiling height, airflow, and smoke transport, so the sequence alone does not prove origin.
Key point: Is data to test origin hypotheses
Reference: NFPA 921 (2024), Active Fire Protection Systems; NFPA 72 (2022), National Fire Alarm and Signaling Code
To arc map a room, the technician first needs to know
Correct answer: D. The routing of each branch circuit is correct because arc mapping interprets arc sites by where they fall along each circuit relative to the panel. That requires tracing each branch circuit from the panel through the room, including the receptacles, switches, and fixtures it fed. Without the routing, the upstream and downstream relationship of arc sites cannot be established.
- A is not correct because panel age does not tell the technician which conductors ran through the room or how they were connected.
- B is not correct because construction date may suggest the wiring type but does not show how circuits run through the room.
- C is not correct because device brand does not affect where arc sites form or how they are interpreted.
Key point: The routing of each branch circuit
Reference: NFPA 921 (2024), Origin Determination
During reconstruction, a nightstand placed where the occupant remembers it leaves a clean floor outline unexplained, while moving it two feet to the left matches the outline exactly. The technician should
Correct answer: A. Follow the physical evidence is correct because a protected outline on the floor is physical evidence of where an item sat during the fire. A placement that leaves the outline unexplained is wrong, and a placement that fits it is supported. The technician documents the occupant's account and the discrepancy, then places the item where the evidence shows.
- B is not correct because an averaged position matches neither the evidence nor the memory and would misplace every pattern tied to the item.
- C is not correct because memory of furniture placement is often off by a few feet, and the outline is physical evidence of where the item actually sat.
- D is not correct because the nightstand is part of the room's fuel and pattern record, so removing it leaves patterns unexplained.
Key point: Follow the physical evidence
Reference: NFPA 921 (2024), Origin Determination
Sections of burned wall studs from one side of a room have fallen into the debris. Reassembling them in their original positions during reconstruction lets the technician
Correct answer: B. Read the patterns as they formed is correct because fire patterns on structural members often run across several pieces, such as a V pattern spanning a row of studs. Once the pieces fall, the pattern is broken up and hard to read. Putting the members back in their original order restores the pattern so it can be interpreted and used in the origin analysis.
- A is not correct because classification comes from the cause analysis, and the reassembled patterns contribute to origin.
- C is not correct because it confuses reconstruction with a damage appraisal; repair estimates are an insurance and contractor matter, while reassembling the studs restores broken patterns so they can be read for origin.
- D is not correct because framing dimensions may hint at age, but reassembly is done to read fire patterns.
Key point: Read the patterns as they formed
Reference: NFPA 921 (2024), Origin Determination
Partially legible nameplate data on a fire-damaged space heater should be photographed and transcribed at the scene. What does this information allow?
Correct answer: D. Finding the model, recalls, and exemplars is correct because the manufacturer, model and serial number let the investigator obtain manuals, find recall or incident history, and locate an exemplar of the same design for comparison. Nameplates can be further damaged or lost during handling, so their data are recorded with close-up photographs while the appliance is still in place. The information is noted with the appliance's location and as-found condition.
- A is not correct because classification comes from analysis of all the data, and a model number cannot establish it.
- B is not correct because ignition temperature is a property of a fuel, and nameplate data describe the appliance.
- C is not correct because heat release rate depends on the fuels burning in the room and cannot be read from a nameplate.
Key point: Finding the model, recalls, and exemplars
Reference: NFPA 921 (2024), Documentation of the Investigation; Appliances
In a fatal fire, the victim is found just inside a closed bedroom door. Along with the body, what condition should be documented?
Correct answer: C. Door position and lock status is correct because whether a door was open, closed or locked affects both fire spread and the victim's ability to escape, and it helps interpret the body's location. Hinges, latch and lock hardware, and protected areas on the door and frame can show its position during the fire. These conditions are photographed and noted before anyone opens, closes or removes the door.
- A is not correct because curtain fabric is a fuel detail with no bearing on whether the victim could open the exit.
- B is not correct because paint color is a finish detail that says nothing about whether the door was open, closed or locked.
- D is not correct because carpet pad thickness is a minor fuel detail that does not explain the victim's position at the door.
Key point: Door position and lock status
Reference: NFPA 921 (2024), Documentation of the Investigation; Fire and Explosion Deaths and Injuries
Years after a contractor installed a water heater vent with too little clearance to wood framing, heat from the vent ignited the framing. How do the cause classification and the question of fault relate?
Correct answer: D. Accidental; responsibility is separate is correct because no one intended to ignite the framing, so the cause is accidental. NFPA 921 treats responsibility, meaning the accountability of a person or entity for the fire or its damage, as a separate question from cause. The installation error is central to responsibility, which may involve codes, listings and installation instructions.
- A is not correct because the failure came from an installation error, which is a human act, while natural covers causes without direct human intervention, such as lightning, earthquake, wind or flood.
- B is not correct because human involvement does not prevent classification; once the vent clearance error is shown to have heated the framing to ignition, the cause is proven and accidental applies.
- C is not correct because an installation error is not an intentional act to set a fire.
Key point: Accidental; responsibility is separate
Reference: NFPA 921 (2024), Analyzing the Incident for Cause and Responsibility; NFPA 921 (2024), Fire Cause Determination
In a storage shed, a bucket of calcium hypochlorite pool shock sat on a shelf directly below a leaking container of brake fluid. The fire began at that shelf with no electrical items nearby. What ignition sequence fits best?
Correct answer: A. Reaction of oxidizer with fluid is correct because calcium hypochlorite is a strong oxidizer that can react vigorously with organic liquids such as glycol-based brake fluid, producing enough heat to ignite. The leak brought the fuel and oxidizer together without any outside ignition source. Such chemical ignition can be accidental, as here, or can be used in incendiary devices, so the storage arrangement and other data decide the classification.
- B is not correct because plastic containers do not self-heat; the heat came from the chemical reaction.
- C is not correct because no electrical items were near the shelf, and chlorine gas is not a fuel.
- D is not correct because brake fluid has a low vapor pressure at shed temperatures, and the chemical reaction explains the fire.
Key point: Reaction of oxidizer with fluid
Reference: NFPA 921 (2024), Fire Cause Determination
During planning for a fire in a manufacturing plant involving a failed industrial furnace, the lead investigator recognizes that analyzing the furnace controls is beyond the team's expertise. The appropriate step is to:
Correct answer: B. Bring in a qualified engineer is correct because NFPA 921 expects investigators to recognize the limits of their expertise and to bring in specialists such as mechanical, electrical or fire protection engineers when needed. Planning includes identifying these needs early so the specialists can see the scene before it is altered. The lead investigator coordinates their work with the rest of the team. Their findings become part of the data analyzed.
- A is not correct because the owner is an interested party whose information is data to be tested, not a substitute for expert analysis.
- C is not correct because an undetermined classification is reached after analysis, not chosen because a specialist was not consulted.
- D is not correct because working beyond one's expertise risks an unsupported opinion when a qualified specialist is available.
Key point: Bring in a qualified engineer
Reference: NFPA 921 (2024), Planning the Investigation
Several interested parties, including insurers and equipment manufacturers, will examine a large loss scene together. Before the joint examination begins, the parties should agree on:
Correct answer: A. Written protocols for evidence and access is correct because NFPA 921 recommends that parties in a major investigation agree in advance on how the scene will be examined, how evidence will be documented, collected and stored, and how information will be shared. Written protocols reduce disputes and claims of spoliation. Safety and access rules are set at the same time. Responsibility and the cause are conclusions that come later, if at all.
- B is not correct because payment for the loss is an insurance matter that does not belong in the scene protocol.
- C is not correct because the cause classification comes from the analysis and cannot be agreed upon before the data is collected.
- D is not correct because responsibility is a later legal or civil question and is not settled before the examination.
Key point: Written protocols for evidence and access
Reference: NFPA 921 (2024), Management of Major Investigations
A branch circuit conductor shows a suspected arc site in the area of origin. When cutting this conductor for collection, the technician should
Correct answer: A. Cut well away from the damaged area is correct because leaving length on both sides protects the damaged area and keeps enough conductor for examination. NFPA 921 calls for documenting conductors in place before cutting. A cut through or near the feature can destroy the evidence it is meant to preserve.
- B is not correct because pulling drags the conductor through debris and framing and can break or deform the damaged area.
- C is not correct because cutting through the bead destroys the feature the lab needs to examine.
- D is not correct because twisting adds new mechanical damage and can be confused with fire effects.
Key point: Cut well away from the damaged area
Reference: NFPA 921 (2024), Physical Evidence; NFPA 921 (2024), Electricity and Fire
Conductor segments collected from the area of origin are tagged at each end. The main purpose of these tags is to show
Correct answer: A. Which end faced the source is correct because the direction toward the panel or power source matters when the lab or investigator interprets arc damage along a circuit. Without end tags, the orientation of a loose segment is lost. Segments are also linked to the diagram so their location in the building can be reconstructed.
- B is not correct because insulation temperature ratings come from printed markings or product specifications and are unrelated to field tags; end tags record orientation, which is lost once a loose segment is removed.
- C is not correct because the time of collection belongs on the evidence label and log, not on end tags.
- D is not correct because melting points are a property of the metal, not something recorded on collection tags.
Key point: Which end faced the source
Reference: NFPA 921 (2024), Physical Evidence; NFPA 921 (2024), Electricity and Fire
In a restaurant fire, the wet chemical suppression system in the kitchen hood discharged. Upon actuation, the system design should also have
Correct answer: A. Shut off fuel or power to cooking appliances is correct because commercial cooking suppression systems are required to shut off gas or electric power to the appliances under the hood when they discharge. Without that shutoff, the appliances could reignite the grease. The investigator checks whether the shutoff worked and documents fusible links, the manual pull station, and the agent cylinder. Service tags give the date of the last inspection.
- B is not correct because wet chemical systems use a stored agent and must be recharged by a service company.
- C is not correct because it assigns the hood system a building function it does not have; hood suppression is tied to shutting off fuel or power to the cooking line, while door hardware is controlled by other building systems.
- D is not correct because sprinklers operate individually from heat, and the hood system does not start them.
Key point: Shut off fuel or power to cooking appliances
Reference: NFPA 921 (2024), Active Fire Protection Systems; NFPA 96 (2024), Standard for Ventilation Control and Fire Protection of Commercial Cooking Operations
A proposed fire scenario has a closed bedroom fire reaching 5 MW, yet the room's only opening is one interior doorway. To test whether that doorway could admit enough air, the investigator uses the relationship that the maximum ventilation-limited heat release rate is roughly proportional to
Correct answer: C. Opening area times the square root of its height is correct because buoyancy-driven flow through an opening depends on both its area and its height, with flow increasing as the square root of height. This term, A times the square root of H, is called the ventilation factor. A common estimate gives the maximum HRR in kilowatts as about 1,500 times A (square meters) times the square root of H (meters). Investigators use it to check whether a proposed fire size was possible with the openings present.
- A is not correct because room volume does not set the steady air inflow; it affects how fast the oxygen already inside is used up.
- B is not correct because airflow through an opening increases with the square root of its height, not the square; squaring the height greatly overstates the effect of tall openings.
- D is not correct because floor area times ceiling height is room volume, which does not control the rate at which fresh air enters through the doorway.
Key point: Opening area times the square root of its height
Reference: NFPA 921 (2024), Basic Fire Science
Once a bedroom fire passed flashover, its burning rate was set by the air entering through the single broken window rather than by the furniture. Compared with the same furniture burning with ample air, the fire in this condition tends to produce
Correct answer: C. More carbon monoxide and soot is correct because when oxygen is limited, carbon in the fuel is not fully oxidized to carbon dioxide. Carbon monoxide yields can be many times higher than in well-ventilated burning. The incomplete products, including soot and unburned pyrolysis gases, can burn later when they reach fresh air.
- A is not correct because carbon monoxide yields rise, not fall, when burning is limited by oxygen.
- B is not correct because complete combustion requires enough oxygen; a ventilation-controlled fire is short of oxygen, so combustion is less complete.
- D is not correct because ventilation-controlled rooms are usually at their hottest, often after flashover, so layer temperatures are high.
Key point: More carbon monoxide and soot
Reference: NFPA 921 (2024), Basic Fire Science
In a burning candle, wax vapor rising from the wick and oxygen from the surrounding air meet and mix at the flame zone itself. This makes the candle flame
Correct answer: D. A laminar diffusion flame is correct because the fuel and oxidizer arrive from opposite sides and the burning rate is controlled by how fast they diffuse together. The candle flame is small and smooth, which reflects laminar flow. Most fires investigators examine, from candles to burning furniture, involve diffusion flames; larger ones become turbulent.
- A is not correct because a candle produces a visible gas-phase flame; glowing combustion occurs on the surface of a solid such as char.
- B is not correct because a premixed flame burns a fuel and air mixture blended before it reaches the flame, as in a Bunsen burner with its air inlet open.
- C is not correct because the candle's fuel and air are not mixed in advance, and its small, steady flame is laminar rather than turbulent.
Key point: A laminar diffusion flame
Reference: NFPA 921 (2024), Basic Fire Science
Score by area
The full course has explained questions like these for every area of the exam, timed practice exams and a diagnostic that shows where to start.
Start your free 3-day trial See what the full course includes
For eligibility, fees and how the exam is scored, read our fire investigator certification guide.
MyTest by Acheron Review is an independent exam preparation company and is not affiliated with, endorsed by or sponsored by the IAAI, NAFI or the NFPA.