These 25 questions come from our IAAI-CFI course bank and are spread across the areas of the exam outline. Answer all 25, press the button at the bottom, and you will see your score by area, the correct answer to each question and the reason every other choice is wrong. No account is needed. The IAAI-CFI exam has no more than 100 true/false and multiple-choice questions, closed book, in 2 hours.
On home oxygen at 3 L/min, a patient was lighting a cigarette with a disposable lighter when his flame-resistant blanket caught fire and burned completely. Defense counsel cites published tests, run under standard laboratory conditions, showing the blanket self-extinguishes after exposure to a lighter-size flame. What most limits the weight of those tests in this case?
Correct answer: D. Tests were run in ordinary air is correct because the fuel and the ignition source must be evaluated under the oxidant conditions that existed at ignition. Oxygen enrichment lowers the energy needed for ignition and raises the burning rate, and materials that self-extinguish in air at about 21 percent oxygen can burn vigorously in an enriched atmosphere. The published results describe the blanket in air, so they cannot answer whether it would ignite and keep burning near the patient's face and chest, where cannula flow enriched the air.
- A is not correct because smoke output bears on tenability and visibility, not on whether a lighter flame could ignite the blanket where oxygen enriched the air.
- B is not correct because even well-reviewed tests answer the wrong question when the oxidant conditions differ, and peer review status does not fix that mismatch.
- C is not correct because heat release data describe fire size after ignition and would not settle whether the blanket ignites in an oxygen-enriched atmosphere.
Key point: Tests were run in ordinary air
Reference: NFPA 921 (2024), Fire Cause Determination
While filling a tiller, a homeowner spilled most of a 5-gallon can of gasoline on a basement floor. About ten minutes later a flash fire started at the gas water heater 15 feet away, just as its burner cycled on. In the cause statement, what is the first fuel ignited?
Correct answer: C. Gasoline vapor that reached the burner is correct because the first fuel ignited is the material the ignition source first raised to ignition, and liquid gasoline does not burn as a liquid. Its vapor, heavier than air, spread along the floor until a flammable mixture reached the burner. The burner flame is the ignition source, the spill and vapor travel make up the ignition sequence, and air is the oxidant. Naming each element separately lets each one be tested against the data.
- A is not correct because the tank was not at the point of ignition and no data place a release there; the vapor that reached the burner came from the floor spill.
- B is not correct because liquids do not burn in the liquid phase; the vapor that traveled from the pool and reached the burner within its flammable range is what ignited first.
- D is not correct because it is the ignition source, and NFPA 921 keeps the heat source and the first fuel as separate elements so each can be tested on its own.
Key point: Gasoline vapor that reached the burner
Reference: NFPA 921 (2024), Fire Cause Determination
Only ash and springs remain where a sofa stood at the origin. To state what the first fuel was and what it was made of, the investigator needs data about the sofa before the fire. Which source is most useful for that purpose?
Correct answer: C. Old photos and owner accounts is correct because when the first fuel is consumed, its identity, materials and arrangement are reconstructed from data gathered outside the debris: photographs, receipts, owner and occupant descriptions and exemplar furniture of the same model. Knowing whether the cushions were polyurethane foam under cotton or under thermoplastic covers decides which ignition sources could have been competent, so this information shapes every later hypothesis test.
- A is not correct because char depth helps with heat exposure and origin analysis, and it cannot say what covering, padding or frame materials the sofa contained.
- B is not correct because arc mapping locates energized conductors to help define the origin, and it does not describe the materials of a piece of furniture.
- D is not correct because laboratory testing for ignitable liquid residues looks for added liquids and cannot reconstruct the sofa's construction or fabric from residue.
Key point: Old photos and owner accounts
Reference: NFPA 921 (2024), Fire Cause Determination
A monitored fire alarm panel in a burned office building was destroyed, and its internal event history cannot be recovered. The investigator still needs the order in which the building's addressable detectors reported. The best remaining source is
Correct answer: B. The central station signal history is correct because a monitored panel transmits alarm, trouble and supervisory signals to a remote receiving center, which logs each signal with its own time stamp and, on addressable systems, often the device or zone. That record survives destruction of the panel. The investigator requests it promptly, confirms the receiver clock against a reference and matches each point to the device layout before using the sequence to test origin hypotheses.
- A is not correct because an annunciator read during suppression gives a snapshot from memory, while the receiving center keeps a time-stamped record of each signal.
- C is not correct because as-built drawings show where each device is located, which is needed to read the signals, but they contain no record of when any device reported.
- D is not correct because inspection reports show that devices worked when tested before the fire and do not record the sequence of alarms during the fire.
Key point: The central station signal history
Reference: NFPA 921 (2024), Active Fire Protection Systems; Origin Determination
The dispatch center's recording of an occupant's 911 call captures her saying the fire is "in the back bedroom closet." Two days later, after talking with relatives, she tells the investigator it started in the hallway. For origin analysis, the recording is most valuable because it
Correct answer: A. Records her account before influence is correct because a statement recorded during the event is made before discussion with others, media reports or self-protective rethinking can reshape memory. The change between the call and the interview must be explained before either version is relied on. The investigator obtains the audio and CAD record promptly, since retention periods vary, and asks the occupant what she saw from where she stood at each point.
- B is not correct because witness data are one source of origin data and must be reconciled with the physical evidence, which can confirm or contradict any account.
- C is not correct because a contemporaneous statement is strong witness data, but it shows where she saw fire, and the origin still has to be tested against patterns, arc data and fire dynamics.
- D is not correct because the call time is a hard time for her report, but the fire had already grown enough to be seen, so ignition came earlier by an unknown interval.
Key point: Records her account before influence
Reference: NFPA 921 (2024), Sources of Information; Origin Determination
Electric resistance heat strips in an attic air handler kept operating after the blower motor seized days earlier, because the thermostat kept calling for heat. Fire damage centered on the heater cabinet and the adjacent duct insulation. The safety controls whose failure should be tested first are the
Correct answer: D. High-limit and thermal cutoffs is correct because electric heat strips depend on blower air to carry heat away. With the blower stopped, the elements overheat, and automatic high-limit switches and one-time thermal cutoffs are designed to open the circuit. Fire at the heater cabinet after a blower failure points to testing whether those devices were present, working, bypassed or welded closed. Exemplar units and laboratory examination help evaluate them.
- A is not correct because a duct smoke detector shuts down the fan when smoke is present, but the blower had already stopped and the hazard was element overheating.
- B is not correct because a thermocouple proves a gas pilot flame, and this air handler uses electric resistance heat with no gas valve.
- C is not correct because a condensate float switch stops cooling when drain water backs up and does not protect against overheated heating elements.
Key point: High-limit and thermal cutoffs
Reference: NFPA 921 (2024), Building Systems
First in alarm on an addressable panel's log was a smoke detector in a second-floor conference room, 40 seconds before a detector in the copy room next door. The copy room door was closed and its return air duct was running. Treating the log as origin data, the investigator should
Correct answer: C. Weigh smoke transport first is correct because detector activation order depends on how smoke traveled, not only on distance from the fire. A closed door can hold smoke in the room of origin while a running return duct carries it to detectors elsewhere. The log is valuable time-stamped data, but the investigator must reconstruct door positions and HVAC operation before treating the first device in alarm as marking the origin.
- A is not correct because the first detector in alarm shows where smoke first reached a detector, which can be a remote room fed by ductwork while the origin room door stays closed.
- B is not correct because the airflow explanation is a hypothesis to test, and the copy room becomes the origin only after patterns and other data support it.
- D is not correct because a properly working panel log is objective data whose meaning depends on smoke transport, so it should be interpreted and kept.
Key point: Weigh smoke transport first
Reference: NFPA 921 (2024), Active Fire Protection Systems; Origin Determination
In January, gas leaking from a cracked main under a frozen, snow-covered street exploded in a house 60 feet away, while houses nearer the leak were unaffected. Excavation shows that the house's sewer lateral crosses the gas main trench. The most likely explanation for this pattern is that:
Correct answer: A. Gas migrated along buried utility paths is correct because gas leaking underground moves along the path of least resistance, such as loose trench backfill, sewer laterals and utility conduits. Frozen or paved ground acts as a cap that blocks venting to the surface and pushes gas sideways for long distances. Gas can then enter a building through a sewer connection or foundation penetration far from the leak. NFPA 921 calls for tracing these migration paths when a gas explosion occurs away from an obvious source.
- B is not correct because nothing suggests the nearer houses resisted pressure better; they were unaffected because the gas did not enter them, as the migration path shows.
- C is not correct because frozen soil and snow cover resist vertical movement, which is why gas spreads sideways under them instead of venting straight up.
- D is not correct because odorant level affects whether occupants smell gas, and it does not explain why gas reached a distant house while closer houses were spared.
Key point: Gas migrated along buried utility paths
Reference: NFPA 921 (2024), Explosions
Propane leaked from a dryer connector in a basement laundry room and ignited. Candidate ignition sources include a water heater pilot 6 inches above the floor, a ceiling light the occupant switched on, a wall thermostat 5 feet up, and a refrigerator upstairs. Given propane's vapor density, the hypothesis to test first is the:
Correct answer: D. Water heater pilot near the floor is correct because propane vapor is heavier than air and tends to collect at floor level, so a continuous flame 6 inches off the floor is the source most likely to meet a flammable concentration first. A standing pilot is also a competent source that needs no action by anyone. The other sources stay on the list and are tested in turn, since NFPA 921 requires each hypothesis to be tested against the data, including the gas layer's likely position.
- A is not correct because thermostat contacts at 5 feet are well above where a heavier-than-air gas first accumulates, and they arc only when the system cycles.
- B is not correct because the refrigerator is on another floor, and heavier-than-air propane would have to fill the basement and climb a stairway before reaching it.
- C is not correct because a ceiling fixture sits in the part of the room where propane is least concentrated early in a leak, so it is less likely to meet a flammable mixture first.
Key point: Water heater pilot near the floor
Reference: NFPA 921 (2024), Explosions
Hired a year after a house fire, a defense expert offers an origin opinion based only on the owner's recorded statement and six scene photographs. He never reviewed the fire department's report, the alarm panel log, the arc survey, or the 200 other photographs in the file. Of the Rule 702 requirements, the one most directly in question is
Correct answer: C. Sufficient facts or data is correct because Rule 702(b) requires that the testimony be based on sufficient facts or data, and the 2023 amendment confirms the judge must find this by a preponderance before the jury hears the opinion. An origin opinion that ignores available alarm records, arc mapping, and most of the photographs rests on a selective basis. NFPA 921 calls for the investigator to collect and consider all available data before forming and testing hypotheses.
- A is not correct because origin opinions are beyond common knowledge and would help jurors, so helpfulness is not the weak point in this scenario.
- B is not correct because qualification can rest on experience or training, and the scenario gives no reason to doubt his background.
- D is not correct because general acceptance relates to the method itself, origin analysis under NFPA 921 is widely accepted, and the gap here lies in the data he reviewed.
Key point: Sufficient facts or data
Reference: Federal Rules of Evidence, Rule 702 (as amended December 1, 2023); NFPA 921 (2024), Basic Methodology
At a pretrial hearing in federal court, the defense challenges the plaintiff's origin and cause expert. The judge notes that Rule 702 was amended effective December 1, 2023, and asks who must establish admissibility and to what standard. The correct answer is
Correct answer: C. The proponent, by a preponderance is correct because amended Rule 702 states that the proponent must demonstrate to the court that it is more likely than not that the testimony meets each requirement: helpfulness, sufficient facts or data, reliable principles and methods, and reliable application to the facts. The Advisory Committee explained that the amendment clarifies the Rule 104(a) preponderance standard that many courts had misapplied. A plaintiff's investigator should expect counsel to prove each element from the file and report.
- A is not correct because the criminal standard of proof has no role in admissibility rulings, which use the Rule 104(a) preponderance standard.
- B is not correct because the amended rule states that the proponent must show the requirements are met, so a challenger need not disprove reliability.
- D is not correct because the party offering the expert carries the burden, and no heightened clear and convincing standard applies to admissibility of expert testimony.
Key point: The proponent, by a preponderance
Reference: Federal Rules of Evidence, Rule 702 (as amended December 1, 2023); NFPA 921 (2024), Legal Considerations
Investigators recovered an e-bike battery pack of several dozen cylindrical cells, many vented and some ejected. To identify which cell failed first while preserving evidence for all parties, the best first step is
Correct answer: B. CT scanning the pack before disassembly is correct because computed tomography shows the internal structure of every cell and its position in the pack without changing the evidence. Patterns such as internal damage, propagation direction and the condition of the jelly roll help locate the cell that initiated thermal runaway. Destructive steps follow only after documentation, under an agreed protocol. Ejected cells are mapped and collected so their original positions can be reconstructed.
- A is not correct because cutting a cell first destroys evidence before the whole pack is documented and may not target the initiating cell.
- C is not correct because cell voltages show which cells still hold charge, not which cell failed first, and probing may disturb the pack.
- D is not correct because charging a fire-damaged pack can trigger new thermal runaway, endangers the examiners and alters the evidence before documentation.
Key point: CT scanning the pack before disassembly
Reference: NFPA 921 (2024), Electricity and Fire
Overnight, a wall-mounted lithium-ion energy storage system in a closed garage failed. Neighbors heard a loud bang, the garage door was blown outward, and only then did fire become visible. The most likely explanation for the sequence is
Correct answer: A. Ignition of accumulated battery vent gas is correct because cells in thermal runaway vent large volumes of flammable gas, including hydrogen, carbon monoxide, hydrocarbons and electrolyte vapor. In a closed space this gas can build to a flammable concentration before ignition, then ignite as a deflagration that damages the structure. Fire follows. Energy storage installation standards address explosion control for this reason. The sequence of explosion before visible fire fits this mechanism.
- B is not correct because nothing places gasoline in the garage, while battery runaway produces the gas volume the sequence requires.
- C is not correct because a BLEVE needs a pressure vessel holding a liquid above its boiling point; battery enclosures are not such vessels.
- D is not correct because arcing at the inverter could ignite something nearby but does not explain an explosion strong enough to blow out the door.
Key point: Ignition of accumulated battery vent gas
Reference: NFPA 921 (2024), Electricity and Fire; NFPA 855 (2023), Standard for the Installation of Stationary Energy Storage Systems
A delivery van caught fire after a 40-minute highway run. The valve cover gasket on the right bank had been leaking motor oil onto the exhaust manifold below it, and the heaviest damage centers on that manifold. The opposing expert argues that hot surface ignition of automotive fluids is rare, so the cause must be electrical. How should the oil leak hypothesis be treated?
Correct answer: A. A credible ignition hypothesis to test is correct because heavier automotive fluids such as motor oil, transmission fluid, power steering fluid and diesel evaporate slowly. They stay in contact with an exhaust manifold or turbocharger long enough to heat, and they can ignite there. NFPA 921 treats gasoline differently: it evaporates and its vapor disperses before it reaches ignition conditions on most hot surfaces. The oil hypothesis still has to be tested against the leak path, deposits and the damage pattern.
- B is not correct because hot exhaust components can supply the ignition energy themselves for oil, transmission fluid and diesel, so no separate flame or spark is required.
- C is not correct because exhaust manifolds on a working engine run hot enough to ignite heavier fluids; the converter is another hot surface but is not a precondition for this hypothesis.
- D is not correct because it borrows the gasoline caution; gasoline evaporates and disperses quickly, while motor oil stays on the hot metal long enough to heat to ignition.
Key point: A credible ignition hypothesis to test
Reference: NFPA 921 (2024), Motor Vehicle Fires
Arc damage is found on a conductor of the blower motor circuit in a burned sedan. On this model the blower circuit is powered only through the ignition switch, with no retained accessory power after shutoff. The owner says the car had been parked with the key removed for two hours. What does the arc site establish?
Correct answer: D. It was energized when damaged is correct because an arc requires current, and this circuit receives power only through the ignition switch. That conflicts with the owner's account. The investigator should examine the ignition switch and key, look for a remote starter or other aftermarket wiring that could feed the circuit, and check for backfeed. Always-hot circuits, such as the starter cable, explain arcs in parked vehicles; switched circuits do not.
- A is not correct because a switched circuit can be energized only through the ignition switch or an added device, so the switch, key and any remote starter now need examination.
- B is not correct because nothing in the finding places a battery cable fault first; the arc sits on a switched circuit and says nothing about the always-hot starter cable.
- C is not correct because an arc shows only that the conductor was energized when the insulation failed; arcing commonly occurs as fire attacks wiring and does not by itself identify the first fuel or ignition.
Key point: It was energized when damaged
Reference: NFPA 921 (2024), Motor Vehicle Fires
A fire began along roof deicing cable near a gutter. The circuit is protected by a ground-fault protection of equipment device set near 30 milliamperes rather than a 5-milliampere personnel GFCI. In the analysis, this device was installed mainly to
Correct answer: D. Limit fire risk from leakage currents is correct because ground-fault protection of equipment is designed to open the circuit when leakage to ground reaches a level that can heat damaged insulation and start fires. Codes require it for fixed outdoor deicing and heat tracing equipment. Its higher trip setting serves fire protection, while personnel GFCIs trip near 5 milliamperes. Whether the device worked is checked by testing and by its condition at the scene.
- A is not correct because overload protection comes from the breaker or fuse on the circuit, and ground-fault sensing does not measure total load current.
- B is not correct because ground-fault devices measure current imbalance between the circuit conductors and do not recognize the waveform signatures of series arcs.
- C is not correct because personnel protection requires trip levels near 5 milliamperes; a 30-milliampere device is designed for equipment and fire protection.
Key point: Limit fire risk from leakage currents
Reference: NFPA 921 (2024), Electricity and Fire; NFPA 70 (2023), National Electrical Code
A small, isolated burn on the carpet sits directly beneath a burned curtain rod, about 6 feet from the main fire area at a sofa. Fabric remnants and curtain hooks lie in the burned spot. A colleague calls it a second point of origin. What is the better explanation?
Correct answer: A. Burning drapery falling to the floor is correct because curtains ignited by the sofa fire can burn through their hooks and fall, igniting the carpet below as drop-down. The fabric remnants, the hooks, and the location under the rod support this. NFPA 921 warns that drop-down produces separate low burns that can be mistaken for additional origins, so the investigator must explain how fire could have reached such areas before calling them separate fires.
- B is not correct because nothing indicates a liquid, and burning fabric falling from above explains a localized floor burn beneath the window.
- C is not correct because multiple origins require evidence of independent ignition, and the debris in the spot shows burning material dropped there from the rod.
- D is not correct because flashover ignites exposed fuels across the whole room, while a single small burn directly under the rod points to material falling from above.
Key point: Burning drapery falling to the floor
Reference: NFPA 921 (2024), Fire Effects and Fire Patterns
In a home office, the deepest char and greatest material loss are at a bookcase packed with paper files, about 10 feet from a desk where witnesses saw the first flames. What most likely explains the heavy damage at the bookcase?
Correct answer: A. Its large fuel load burned longer is correct because a dense fuel package such as packed paper releases heat for a long time once involved, producing deep char and material loss even when it ignites late. The amount of damage reflects how much fuel burned and for how long, not where the fire started. NFPA 921 cautions against equating the area of greatest damage with the origin without considering fuel load, ventilation, and suppression timing.
- B is not correct because paper files burn deeply without help, and a liquid would need laboratory support rather than inference from damage.
- C is not correct because arcing in a circuit is a brief, localized event and does not cause deep char across a whole bookcase.
- D is not correct because witnesses saw the first flames at the desk, and heavy damage at a large fuel load does not by itself make the bookcase the origin.
Key point: Its large fuel load burned longer
Reference: NFPA 921 (2024), Fire Effects and Fire Patterns
An investigator comparing an older smoke alarm with a newer replacement learns that alarms listed to the 8th edition of UL 217 had to pass tests earlier models did not. Those added tests include
Correct answer: B. Cooking nuisance and foam fires is correct because the 8th edition of UL 217 added a cooking nuisance test, using broiling hamburgers, during which a listed alarm must not sound, plus smoldering and flaming polyurethane foam fire tests that it must detect. The aim was to cut the nuisance alarms that lead people to disable alarms while keeping response to modern furnishing fires. The listing edition of a recovered alarm is data on its expected performance.
- A is not correct because heat alarm performance falls under separate listing requirements, and the UL 217 changes concerned smoke and cooking tests.
- C is not correct because carbon monoxide alarms are covered by UL 2034, and smoke alarm listing does not require CO response.
- D is not correct because ten-year sealed batteries are required by some state laws, not by the added UL 217 fire and nuisance tests.
Key point: Cooking nuisance and foam fires
Reference: UL 217 (8th edition), Standard for Smoke Alarms; NFPA 72 (2022), National Fire Alarm and Signaling Code
Investigators planning a test burn want thermocouples that capture the hottest part of the ceiling jet 3 m from the plume centerline beneath a 3 m ceiling. The best placement is
Correct answer: C. Close to the ceiling surface is correct because an unconfined ceiling jet is a thin layer, only a small fraction of the ceiling height thick, and its peak temperature and velocity occur very near the ceiling. Right at the surface the jet loses some heat and speed to the ceiling, and farther down it mixes with room air and cools. Heat detectors and sprinklers are mounted close to the ceiling for this reason, and test instruments should be placed the same way.
- A is not correct because midway sits in or below the descending layer, where temperatures are lower than in the ceiling jet carrying heat along the ceiling.
- B is not correct because 1 m is a third of this ceiling height, well below the thin ceiling jet, where gases are cooler and mixed with room air.
- D is not correct because the layer interface is where hot and cool gases meet, which is the coolest part of the hot layer and not its hottest flow.
Key point: Close to the ceiling surface
Reference: NFPA 921 (2024), Basic Fire Science
Beneath a smooth 3 m ceiling, with flames well below it, gas temperatures directly above a steady fire and 0.4 m from the plume centerline are nearly equal, while 3 m out they are much lower. Alpert's correlations explain this because the 0.4 m point lies within
Correct answer: A. The ceiling impingement region is correct because Alpert's correlations treat the area within about r/H = 0.18 of the centerline as the turning region, where the plume strikes the ceiling and the temperature rise is about 16.9 Q^(2/3) / H^(5/3), independent of radius. Here 0.4 m / 3 m = 0.13. Beyond that, the ceiling jet spreads radially and cools as it entrains air and loses heat to the ceiling, with temperature rise falling roughly as r^(-2/3).
- B is not correct because the radial ceiling jet flow region begins beyond r/H of about 0.18, where temperature falls with distance, which describes the 3 m point and not the 0.4 m point.
- C is not correct because the continuous flame region lies low in the plume near the fuel, and the stem places the flames well below this ceiling.
- D is not correct because the cool lower layer is near the floor and does not describe conditions in the gases just beneath the ceiling.
Key point: The ceiling impingement region
Reference: NFPA 921 (2024), Basic Fire Science
Burn patterns indicate fire spread from a bedroom into the hallway, but a neighbor reports seeing flames first at the hallway window. How should the investigator respond to this conflict?
Correct answer: A. Seek data that explains both accounts is correct because the scientific method requires the final hypothesis to explain every data set. The investigator can reexamine the patterns, check what the neighbor could see from that position and when, look for ventilation or flashover effects at the window, and review alarm data or video. Neither the patterns nor the witness wins by default; the explanation that fits all the data is the one to carry forward.
- B is not correct because undetermined is appropriate only after the data have been analyzed and hypotheses tested, and here additional data are still available.
- C is not correct because witnesses can misjudge where flames first appeared, especially when fire is seen through an opening that vents a room deeper in the building.
- D is not correct because patterns can be misread because of ventilation and post-flashover effects, so they cannot be presumed to outweigh an observation.
Key point: Seek data that explains both accounts
Reference: NFPA 921 (2024), Basic Methodology
Cell phone video shows a fire in a round waste container 0.5 m in diameter producing mean flame heights of about 2.0 m. Rearranging Heskestad's correlation, L = 0.235 Q^(2/5) - 1.02 D, the heat release rate was about
Correct answer: C. 370 kW is correct because solving for Q gives Q^(2/5) = (L + 1.02 D) / 0.235 = (2.0 + 0.51) / 0.235 = 10.68, so Q = 10.68^(5/2) = 10.68^2 x square root(10.68) = 114 x 3.27 = about 373 kW. Video estimates carry real uncertainty, because flame tips fluctuate and must be averaged over time to approximate the mean height. The result is best reported as a range and compared with test data for similar containers.
- A is not correct because it drops the 1.02 D term, treating the container as a point source and understating the heat needed for 2.0 m flames from a 0.5 m base.
- B is not correct because it raises 10.68 to the third power instead of the five-halves power, which is the inverse of the two-fifths exponent.
- D is not correct because it subtracts 1.02 D from the flame height instead of adding it when rearranging, a sign error that cuts the result by more than two-thirds.
Key point: 370 kW
Reference: NFPA 921 (2024), Basic Fire Science
After collecting a comparison sample of vinyl flooring from a hallway, the technician must package it. The correct handling is to place it in
Correct answer: C. Its own sealed, labeled can is correct because the comparison sample must stay isolated from the test samples and keep its own vapors. A separate airtight container prevents transfer between samples, and labeling it as a comparison sample, with its location recorded on the diagram and in the photo log, tells the laboratory how to use it. Clean tools and gloves are used for each sample.
- A is not correct because an unsealed container loses volatile compounds and can pick up vapors during storage and transport.
- B is not correct because sharing a can lets vapors move between the comparison material and the test sample, which defeats the comparison.
- D is not correct because paper is permeable, so volatile compounds escape from the sample and outside vapors can enter during storage and transport.
Key point: Its own sealed, labeled can
Reference: NFPA 921 (2024), Physical Evidence
A certified canine alerts strongly at one spot in the origin area, and the working hypothesis is that gasoline was poured there. Three samples from the spot are analyzed, and no ignitable liquid residue is identified. In the report, the alert should be treated as
Correct answer: A. An unconfirmed screening result is correct because NFPA 921 holds that a canine alert not confirmed by laboratory analysis should not be considered validated. The alert can be documented as part of the scene record, but the poured gasoline hypothesis is not supported by the physical evidence. Arguing that the dog detects levels below the laboratory's limits does not make the alert usable as proof, because an alert identifies no compound and cannot be retested by another party.
- B is not correct because an alert that the laboratory did not confirm cannot support a finding that a liquid was present, let alone a classification.
- C is not correct because a laboratory identification is the confirming test, and an unconfirmed alert does not carry equal weight against a negative result.
- D is not correct because claims that dogs exceed laboratory sensitivity do not turn an alert into evidence, since the alert names no compound and cannot be verified.
Key point: An unconfirmed screening result
Reference: NFPA 921 (2024), Physical Evidence
Score by area
The full course has explained questions like these for every area of the exam, timed practice exams and a diagnostic that shows where to start.
Start your free 3-day trial See what the full course includes
For eligibility, fees and how the exam is scored, read our fire investigator certification guide.
MyTest by Acheron Review is an independent exam preparation company and is not affiliated with, endorsed by or sponsored by the IAAI, NAFI or the NFPA.